Latest Posts

Temperature Instruments An Interactive Guide to Instrumentation & Control : Back to Basics

Interactive Guide to Temperature Instruments TempSense Guide Introduction Instrument Explorer Comparison Hub Application Guide IntroductionInstrument ExplorerComparison HubApplication Guide...

Ultrasonic vs Thermal mass flowmeter : Flare flow measurement comparison

Flare Gas Flow Metering: Ultrasonic vs. Thermal Mass Flare Gas Flow Metering Systems A Comprehensive Analysis of Ultrasonic vs. Thermal Mass Technologies 1. The Challenge of Flare Gas Measurement...

Thermal Mass flowmeter : Back Basics Series

Thermal Mass Flowmeter Principle for Flare Gas Comprehensive Guide: Thermal Mass Flowmeters (TMFM) Life-Cycle Principle, Design, Selection, and Field Management for Critical Applications like Flare...

Common Mistakes Engineers Make During Job Applications

Common Mistakes Engineers Make During Job Applications — How to Avoid Them Career Playbook for Engineers Common Mistakes Engineers Make During Job Applications — And Exactly How to Fix Them From...

Try our new FREE Engineering TOOLS

Material Take Off Generator (MTO)

Instrument Hook-up MTO Generator Instrument MTO Generator Generate a Consolidated Material Take Off 1. Select Instruments & Quantities Add New Type Select All Deselect All Reset Generate...

Instrument Datasheet – Comprehensive I&C Engineering Checklists for EPC Projects

Universal Instrument Datasheet — Final Self-Verification Checklist Universal Instrument Datasheet — Final Self-Verification Checklist Applies to pressure/temperature/flow/level transmitters; control...

Generate I&C Deliverables Need for Conceptual, FEED, and Detailed Design.

I&C Project Deliverables Generator (Single-File) I&C Project Deliverables Generator Layout preserved. DCS IO: FEED → “Preliminary IO Schedule — DCS”; no DCS preliminary IO in Conceptual. 1)...

SIL Determination TOOL Using Risk Matrix – IEC 61511

Interactive SIL Determination Application SIL Determination Hub Home Framework Calculator Lifecycle HomeFrameworkCalculatorLifecycle Understanding Functional Safety This application translates the...

Flow meter selection Chart

Infographic: How to Choose the Right Flow Meter The Engineer’s Guide to Flow Measurement Choosing the right flow meter is critical for efficiency, safety, and profitability. This guide...

Accuracy Calcualtor

Transmitter Accuracy Checker (SI · O&G) Transmitter Accuracy Checker SI units · Oil & Gas · IEC/ISA lens · Accuracy threshold is derived from the selected model. 1) Select Instrument &...

IEC 61508 SIL Risk Graph Tool (C/F/P/W, Low-Demand)

SIL Risk Graph Calculator · IEC 61508 (C/F/P/W) SIL Risk Graph Calculator IEC 61508 C/F/P/W method. Choose levels and click Calculate to get the resulting SIL. (Orientation aid only; validate per your...

PFDavg calculations for your Safety Instrumented Functions (SIF)

SIF PFDavg Calculator (1oo1, 1oo2, 2oo2, 2oo3) SIF PFDavg Calculator MVP Project Name SIF Tag Number Preparer Date λd Units FIT (failures / 109 hours)1/hr Changing this converts λd numbers in-place...

SIL Determination using Layer of Protection Analysis (LOPA)

Interactive LOPA & SIL Determination Tool Interactive LOPA & SIL Determination Tool Section 1: Foundational Concepts of LOPA 1.1 The Philosophy of Defense-in-Depth The core principle...

Personal Growth

No posts found.

Section Title

No posts found.

Control Valves

No posts found.

Cyber Security

No posts found.

Functional Safety

No posts found.

Section Title

No posts found.

Pressure

No posts found.

Temperature

No posts found.

Question and Answers

Seebeck Effect – Top 20 Common Interview Questions

Seebeck Effect: Top 20 Common Interview Questions The Seebeck effect, a cornerstone of thermoelectricity, is a frequent topic in interviews for roles in physics, materials science, and engineering...

HART Top 10 Q&A for Temperature Transmitters

HART Temperature Transmitters: Top 10 Questions Answered Answering the most critical questions surrounding the operation, calibration, and benefits of HART-enabled temperature transmitters in...

Common Errors in Temperature Loops – Top 20 Q&A Show thinking

Mastering Temperature Control: A definitive Q&A on the Top 20 Common Errors in Temperature Loops Vellore, India – Achieving and maintaining precise temperature is a critical parameter in a vast...

How to Select Temperature Instruments – Top 25 FAQs

Temperature Measurement: Your Top 25 Questions Answered Choosing the right temperature instrument is a critical decision in countless industrial, scientific, and commercial applications. From ensuring...

RTD 2-Wire vs 3-Wire vs 4-Wire – Top 20 Q&A

RTD Wiring Explained: A Head-to-Head Comparison of 2-Wire, 3-Wire, and 4-Wire Configurations In the realm of precise temperature measurement, Resistance Temperature Detectors (RTDs) are a cornerstone...

Thermowell Selection and Sizing – Top 25 Q&A Guide

Thermowell Selection and Sizing: Your Top 25 Questions Answered A definitive guide to understanding the critical aspects of choosing and sizing thermowells for accurate and reliable temperature...

Field Issues in Temperature Measurement – Top 20 Q&A

Field Issues in Temperature Measurement: Top 20 Questions & Answers Vellore, Tamil Nadu, India – Accurate temperature measurement is a critical parameter in countless industrial processes...

Top 20 Loop Check Q&A for Temperature Instruments

Top 20 Loop Check Q&A for Temperature Instruments: A Comprehensive Guide For instrumentation technicians and engineers, a thorough understanding of loop checking for temperature instruments is...

Thermocouple Cold Junction Compensation? Top 20 Q&A Explained

Thermocouple Cold Junction Compensation: Unveiling the Top 20 Questions Thermocouples are the workhorses of temperature measurement in countless scientific and industrial applications. Their...

Back To Basis

No posts found.

Tools and Calculators

No posts found.

Hazard and Risk assessments

No posts found.

Process Knowledge

No posts found.