Loop Checking and Troubleshooting Quiz

Top 30 Loop Checking and Troubleshooting Quiz

Test your knowledge in industrial control loop checking and troubleshooting. Select the best answer for each question and click "Submit Quiz" at the bottom to see your score and the correct answers.


1. What is the primary purpose of a "cold loop check"?

2. During a "hot loop check," what is the main objective?

3. Before starting any loop checking or troubleshooting activity, what is the most critical first step?

4. A standard 4-20 mA current loop is used for signal transmission. What does a reading of 4 mA typically represent?

5. While troubleshooting a 4-20 mA loop, you measure 0 mA. What is the most likely cause?

6. A technician is using a HART communicator to check a smart transmitter. What is one of the key advantages of using this tool?

7. A control loop is exhibiting continuous oscillation with a constant amplitude and period. What is a probable cause?

8. What does the term "stroking a valve" refer to in the context of loop checking?

9. When troubleshooting a control valve that is not responding to the controller's output signal, what should be checked first?

10. What is the purpose of a loop-powered device?

11. A pressure transmitter with a calibrated range of 0 to 100 psi is reading a steady 12 mA. What is the corresponding pressure value?

12. "Bumpless transfer" is a feature in a controller that ensures:

13. A temperature control loop is slow to respond to changes in the setpoint. Which PID parameter would you most likely adjust to improve the response speed?

14. What is the primary function of a shield wire in an instrument signal cable?

15. If a control valve is "fail-open," what will it do in the event of a loss of the control signal (e.g., air pressure)?

16. While checking a loop, a technician finds that the Process Variable (PV) displayed on the DCS is the negative of the actual value. The most probable cause is:

17. What does the term "stiction" in a control valve refer to?

18. A "loop diagram" is a document that primarily shows:

19. When troubleshooting a noisy process variable signal, which of the following is a good first step?

20. In a PID controller, what is the primary function of the Derivative (Rate) action?

21. A technician is asked to verify the calibration of a differential pressure transmitter used for flow measurement. What equipment is essential for this task?

22. An "I/P transducer" is a device that converts:

23. What is "integral windup" in a PID controller?

24. The Ziegler-Nichols method is a popular technique for:

25. A multimeter is set to measure DC voltage and is connected in parallel with a 250-ohm resistor in a 4-20 mA loop. If the meter reads 2.5 V, what is the loop current?

26. Which of the following is a key safety consideration when working with intrinsically safe (IS) loops?

27. A control loop is in "cascade control." This means:

28. If a transmitter's output signal is "jumpy" or erratic, but the process itself is known to be stable, a possible cause is:

29. What is the primary purpose of a "bench calibration"?

30. When a final control element, like a control valve, is oversized for the application, it can lead to: