Recent Updates
Junction Box Calculator Junction Box Requirement Calculator Enter your I/O details and configuration to determine the required number of JBs. 1. Select System Type DCS IPS FGS 2. Total I/O Counts Analog Inputs (AI) Analog Outputs (AO) Digital Outputs (DO) Total Digital Inputs (DI) … of which are IS 3...
DCS/IPS System & Cabinet Calculator DCS/IPS System & Cabinet Calculator Estimate your hardware needs based on I/O counts. ⚙️ Configuration AI Ch/Module AO Ch/Module DI Ch/Module DO Ch/Module Modules/System Points/Cabinet 🔢 I/O Counts Analog Inputs (AI) Analog Outputs (AO) Digital Outputs (DO) Digital Inputs (DI) Digital Inputs (DI) – Non-IS...
Advanced Instrumentation I/O Calculator Advanced I/O Calculator Calculate standard and F&G device I/O with IS/Non-IS breakdown. I/O Configuration Instrument Type Qty Analog In (AI) Analog Out (AO) Digital In (DI) Digital Out (DO) Actions IS Non-IS IS Non-IS IS Non-IS IS Non-IS Add Custom Instrument Instrument Name Qty AI (IS)...
Reynolds Number Calculator Reynolds Number Calculator Fluid Density (ρ) in kg/m³: Fluid Velocity (v) in m/s: Pipe Diameter (D) in meters: Dynamic Viscosity (μ) in Pa.s: Calculate Reynolds Number...
4-20mA Calculator 4-20 mA Calculator Convert Process Value (%) to Current (mA) Process Value (0-100%) Current Value 4.00 mA...
Pressure Transmitter Range Calculator Pressure Transmitter Range Calculator Process Pressure – Minimum: Process Pressure – Normal: Process Pressure – Maximum: Design Pressure: Select SI Unit: barmbarkPaPa Margin on Top of Highest Pressure (%): Calculate Range Calculated Instrument Range: Lower Range Value (LRV): Upper Range Value (URV):...
DP Level Transmitter Range Calculator DP Level Transmitter Range Calculator Select Tank Type: Open TankClosed Tank (Dry Leg)Closed Tank (Wet Leg / Suppression) Measurement Range (H): The distance from the 0% level to the 100% level (in mm). Process Fluid Specific Gravity (S.G.): The specific gravity of the liquid being...
Cable Conductor Size Calculator Cable Conductor Size Calculator Current (A): Distance (One-way, meters): Voltage (V): Voltage Drop (%) Allowed: Phase: Single PhaseThree Phase Conductor Material: Copper (0.0175 Ω·mm²/m)Aluminium (0.0282 Ω·mm²/m) Calculate Conductor Size...
How to Read P&IDs for Flow Instruments: A Complete Guide (2025) In the intricate world of process industries, from sprawling chemical plants to the precise operations of a pharmaceutical facility, maintaining control over fluid flow is paramount. The roadmap to understanding and managing this critical aspect of any process lies...